Microplate washer / microtiter plate washer

TriContinent’s MultiWash III microplate washer (microtiter plate washer) is designed and manufactured for dependable accuracy, flexibility, and convenient operation. TriContinent has designed and manufactured quality microplate washers since 1992.

  • 8- or 12-port plate washer/dispenser
  • For use with multiple solutions for repetitive dispensing
  • 50 pre-programmed, but user-definable wash programs
  • Manufactured under ISO 13485 quality system
  • Industry-leading two-year warranty

TriContinent MultiWash III Microplate Washer/Microtiter Plate Washer

TriContinent has designed and manufactured quality microplate washers since 1992.

  • Simplicity -- The MultiWash III microplate washer (microtiter plate washer) offers unique design features including, color-coded quick-connect fittings, programming of routines, and a single-button rinse, allowing for simplified lab operations.
  • Flexibility -- The MultiWash III microplate washer (microtiter plate washer) offers 8 and 12-port manifolds, in both standard and coaxial configurations.
    These manifold selections allow your lab to use one microplate washer for a variety of test routines.
  • Productivity -- The MultiWash III microplate washer (microtiter plate washer) has the capability to perform a 300 μL three-cycle wash on a full 96-well plate in less than two minutes,
    and with our optional four-liter wash reservoir, your lab will increase its test throughput and reduce maintenance time.

With 50 programmable wash routines and extensive washing capabilities, the MultiWash III microplate washer is an ideal choice for labs that perform a variety of test routines including:

  • Elisa
  • Cell Washing
  • Cytoxicity tests
  • EIA, FIA and LIA
  • Agglutination tests

Specifications

Maximum Dispense Volume

50 μL - 400 μL with standard manifold (recommended)


50 μL - 1990 μL with 8-port coaxial manifold


50 μL - 1650 μL wtih 12-port coaxial manifold

Weight

12 lbs or 4.5 kg (instrument only)


21 lbs or 8.2 kg (domestic shipping weight)


25 lbs or 9.9 kg (international shipping weight)

Dimensions (instrument only)


Height

9.5 in. (242 mm)

Width

11.5 in. (292 mm)

Depth

16.0 in. (406 mm)

Wash and Rinse Reservoir Volumes

Wash / Rinse / Waste - 2 liters each

Fluid Contact Materials

Glass

Contents

Reservoir Kit F (standard reservoir kit)


2 Power Cords (1 each USA / Japan & European


Spare Fuses


Soakig Microstrip Wells


Operations and Maintenance Manual

Functional Parameters

Full Plate processing speed time

180 seconds with 8-port manfold

Performance


Accuracy

+ 3% at 300 μL

Precision

< 3% at 300μL 

Residual Volume

< 3 μL per well with standard manifold

Soak Time

0- 999 seconds

Number of Wash Cycles

10 wash cycles

Number of Programs

50 pre-programmed

MultiWash III

Catalog #

Description

820

Without Manifold

0820-01

With 8-Port Standard Manifold

0820-02

With 12-Port Standard Manifold

0820-04

With 8-Port Coaxial Manifold

0820-05

With 12-Port Coaxial Manifold

Manifolds

Catalog #

Description

835

8-Port Standard

836

12-Port Standard

838

8-Port Coaxial

839

12-Port Coaxial

Accessories

Catalog #

Description

Quantity

509

105 μM Filters, 10 / Pack

1

721

Clear Dispense Needles, 0.020” I.D. with Installation Tool

1


16 / pack


933

Reservoir Kit F

1


Includes: One each Waste Rinse and Wash bottle



tubing, slip connectors and fittings.


934

Replacement Wash Reservoir Cap assembly with slip connectors for use with Kits E and F

1

935

Replacement Rinse Reservoir Cap assembly with slip connectors for use with Kits E and F

1

936

Replacement Waste Reservoir bottle and cap with slip connectors for use with Reservoir Kits E and F

1

943

Maintenance Kit and Syringe Assembly (Cat#'s 0944 and 0945)

1


No tubing included.


944

Maintenance Kit w/out Syringe Assembly.

1


Includes: Four each inlet filters, thumbscrews and microstrip wells. Two each fuses, valves, valve convers, cleaning needle assemblies and needle installation tools. 16 needle shroud assemblies.


945

Replacement Syringe Assembly

1


Includes: One each valve cover and syringe set and two thumbscrews.


946

Replacement Tubing Kit

1

MultiWash Warranty Information

TriContinent operates an ISO 13485 registered manufacturing facility that delivers the highest quality products.

We stand behind the MultiWash with a 2-year warranty. During the warranty period, should a MultiWash fail, call us with an explanation of malfunction and TriContinent will issue a Return Material Authorization (RMA) number for repair or replacement at our discretion. Do not attempt to repair the instrument, removing the case from the instrument will void the warranty.

It is the responsibility of the customer to determine the suitability of an application and the material compatibility of our product with your application.

When returning a product for repair or replacement, please contact TriContinent Customer Service to receive and RMA number. When calling please be sure to have the following information available:

  • Catalog Number
  • Serial Number
  • Explanation of Malfunction

TriContinent will not accept the return of any product with out prior approval. TriContinent reserves the right to refuse a return of product that has been used with infectious microbiological or radioactive substances or any other materials that may be deemed hazardous. A minimum repair charge may occur for products returned for complaints that cannot be verified by TriContinent.

The RMA number should be referenced on the outside of the shipping container when returning to TriContinent.

Warranty Exclusions

The above warranty shall not apply for defective products resulting from:

  • Improper or Inadequate maintenance by the customer
  • Unauthorized maintenance or service
  • Customer misuse
  • Operation outside of the environmental spefications for the product
  • Instruments returned without proper packaging

There is no warranty expressed for the following components:

  • Valves
  • Syringes
  • Plungers/Seals

Note: For equipment damaged in shipping, please contact the shipper directly.

Technical Data

<table>

<thead>

<tr>

<th>OEM requirements</th>

<th>25 unit minimum order</th>

</tr>

</thead>

<tbody>

<tr>

<td></td>

<td>5 unit minimum per shipment</td>

</tr>

<tr>

<td>Customization is available on below options. A one-time setup charge may apply for each customized area selected.</td>

<td></td>

</tr>

<tr>

<td>Panel Overlay</td>

<td>Retail</td>

</tr>

<tr>

<td></td>

<td>OEM/Generic</td>

</tr>

<tr>

<td></td>

<td>Custom</td>

</tr>

<tr>

<td>Manifold</td>

<td>8-port Standard or Coaxial</td>

</tr>

<tr>

<td></td>

<td>12-port Standard or Coaxial</td>

</tr>

<tr>

<td>Manifold Label</td>

<td>Retail</td>

</tr>

<tr>

<td></td>

<td>OEM/Generic</td>

</tr>

<tr>

<td></td>

<td>Custom</td>

</tr>

<tr>

<td>Power Cord</td>

<td>US/Japan</td>

</tr>

<tr>

<td></td>

<td>European</td>

</tr>

<tr>

<td>Operation Manual</td>

<td></td>

</tr>

<tr>

<td>Quick Start Guide</td>

<td></td>

</tr>

<tr>

<td>Custom Software</td>

<td></td>

</tr>

<tr>

<td>Packaging Labels</td>

<td></td>

</tr>

</tbody>

</table>